Skip to content

ChemLINE 784 ES


ChemLINE 784 ES (Elevated Service) delivers exceptional resistance to aggressive chemicals and elevated temperatures, helping preserve product purity and protect steel with a durable, field-repairable barrier.

02Why It Matters

Patented Polymer Technology, Elevated

ChemLINE 784 ES is formulated with unique polymer technology, designed and engineered with high functionality at elevated service temperatures

ChemLINE 784 ES is engineered for aggressive chemical environments where elevated operating temperatures place greater demands on the lining system. Leveraging the same highly cross-linked polymer functionality as ChemLINE 784, it provides a durable, chemically resistant barrier designed to maintain protective performance under prolonged thermal exposure and demanding service conditions.

 

 

Higher Crosslink Density Means

  • Higher chemical resistance
  • Higher temperature resistance
  • Higher reactivity at lower temperature
  • Higher resistance to absorption
  • Higher toughness
  • Resists under-creep corrosion

03Applications & Use Cases

Where ChemLINE 784 ES performs.

Primary Industries

  • Chemical Processing
  • Paper & Pulp
  • Steel
  • Mining

Asset Types

  • Tanks and flare tanks
  • Reactor vessels
  • Hazardous waste hauling
  • Digesters and black liquor tanks
  • Bleaching systems
  • Pickling tanks and acid storage
  • Acid tanks and scrubbers

Recommended Environments

  • Dry heat resistance to 400°F (204°C)
  • High-temperature immersion service
  • Acids, alkalies, and solvents
  • Wear and abrasion environments
  • High-impact applications

04Application Guidance

Operational requirements for a benchmark application.

Mixing Instructions

  • Material components supplied in pre-measured units
  • Mix ratio: 1:1 by volume (A:B)
  • Use heated plural component spray equipment
  • Material temperature: 150–160°F (65–71°C)

Environmental Conditions

  • Substrate temperature: 50–120°F (10–49°C)
  • Relative humidity: <85%
  • Surface must be 5°F above dew point
  • No application during precipitation

Equipment Recommendations

  • Graco Reactor E-30 or equivalent
  • Heated hose length: 50–100 ft maximum
  • Spray tip size: 0.037–0.043 inch
  • Air pressure: 2000–3000 PSI

Cure Guidance

  • Initial cure: 4–6 hours @ 70°F
  • Return to service: 48 hours @ 70°F
  • Full chemical resistance: 7 days
  • Cooler temperatures extend cure time

Need application guidance?

Contact our technical team for expert support.

Contact Technical Support

05Documentation & Resources

Everything your spec team needs.

06Proof & Validation

When you need superior protection.

Case Study

Tailored In-House Testing: ChemLINE® 784 ES Offers Superior Protection for Aggressive Waste Stream Environments

When a major hazardous waste disposal provider experienced ISO tank liner failure within a year of service, APC ran a tailored 192-day in-house immersion study comparing ChemLINE® 784 and ChemLINE® 784 ES against an aggressive waste stream, with no signs of coating breakdown observed.

Read the case study →
24/7

Technical support available 24/7 for application guidance, specification review, and project planning. Field application assistance and inspector training available.

Talk to our team →

06Proof & Validation

Experience you can trust.

2,500+
Vessels Protected
50M+
Square Feet Installed
25+
Years in Service
95+
Cargo Types Approved
Case Study

Global Chemical Tanker Fleet Conversion

120 vessel fleet conversion from epoxy to MarineLINE 784. Zero cargo contamination incidents over 8 years. 42% reduction in tank cleaning time.

Case Study

High-Temperature Vegetable Oil Service

15-year continuous service in heated vegetable oil cargo tanks. No coating degradation or product contamination. Service temperature 180°F sustained.

Certifications

USCG 46 CFR 30.10-15 Approved IMO Type 2 Approved FDA CFR 21 Compliant IMO PSPC Compliant USDA Approved NSF/ANSI 61 Certified

Independent Testing

  • ASTM D4541 Adhesion Testing: >1000 PSI pull-off strength
  • ASTM D522 Mandrel Bend: Passes 1/8" mandrel with no cracking
  • ASTM D2794 Impact Resistance: 160 in-lbs direct/reverse
  • Independent chemical immersion testing: 95+ cargo types validated
24/7

Technical support available 24/7 for application guidance, specification review, and project planning. Field application assistance and inspector training available.

Talk to our team →

08Related Products

Explore the MarineLINE® family.

01Technical Specifications

Engineered to a tightly knit, impermeable structure.

Coating Type 100% Solids Polyurea
Recommended DFT 60–80 mils (1.5–2.0 mm)
Service Temperature -40°F to 250°F (-40°C to 121°C)
Mixing Ratio 1:1 by volume
Solids Content 100% by volume
Cure Time 48 hours @ 70°F (21°C)
Application Method Plural component spray
Surface Profile SSPC-SP10 2–3 mils
VOC 0 g/L
Recoat Window 24–72 hours
Pot Life N/A (spray applied)
Coverage Rate 16 sq ft/gal @ 60 mils

MarineLINE: The cargo tank lining technology that changed the industry


MarineLINE® is engineered for chemical and product tankers carrying a wide range of high-value and aggressive cargoes. 
cargo-ship
cta-billboard-placeholder

MarineLINE: The cargo tank lining technology that changed the industry

billboard-placeholder-3

For more than three decades, it has set the standard for cargo tank protection, delivering proven performance across complex chemical exposures and trading conditions.

Designed to resist chemical degradation with nearly zero absorption, MarineLINE® helps maintain tank integrity and preserve cargo flexibility. Its advanced polymer technology supports faster, more efficient cleaning and shorter turnaround times between cargoes, helping vessels stay productive across changing trade demands.

 

From specialty chemicals and methanol to refined products, MarineLINE® provides consistent, long-term protection backed by extensive chemical resistance data, technical documentation, and hands-on expert support.